Research Centre for Clinical Kinaesiology
The RCCK is a movement analysis laboratory which can be used to measure characteristics of any kind of human movement such as walking, jogging, sit-to-standing and standing balance for purposes of clinical rehabilitative research.
Offer
Enw | Brand/model | Manylion |
---|---|---|
6 metre mat to measure footstrikes | Gaitrite Platinum | Mobile unit. Needs expert user. |
Artinis Near Infrared Spectroscopy | Artinis Near Infrared Spectroscopy | Requires expert user and callibration. Involved set-up. |
Dell Vicon PC | Dell Vicon PC | Specialist software. Not on general network. |
Digital optical tracking system | Vicon 8 Camera digital optical tracking system | Infra-red based tracking of reflective markers to record human movement. Direct daylight has detrimental effect on performance of equipment. |
Electro-myography equipment | Noraxon 8 Channel EMG Units x 2 | Requires expert user to oversee use for electrode placement. |
Electro-myography equipment Megawin EMG 8 | Megawin EMG 8 Channel Muscle Tester x 2 | Requires expert user to oversee use for electrode placement. |
Electro-myography equipment Megawin EMG 4 | Megawin EMG 4 Channel Muscle Tester x 2 | Requires expert user to oversee use for electrode placement. |
In-shoe pressure measurement system | Pedar X Unit | Callibration needed. Requires expert user. |
In-shoe pressure measurement system Pedar C Unit | Pedar C Unit | Callibration needed. Requires expert user. |
Kistler Force Platforms | Kistler Force Platforms | Not portable - fixed to lab floor |
Muscle strength measurement using controlled resistance | Biodex | Very heavy - therefore needs to be moved and callibrated by supplying company. Not portable. Specific power-supply requirements. |
Muscle strength measurement using controlled resistance Kincom 125E | Kincom 125E | Very heavy - therefore needs to be moved and callibrated by supplying company. Not portable. Specific power-supply requirements. |
Novel Emed Plate | Novel Emed Plate | Callibration requirements. |
Portable system for respiratory analysis | Respiratory cosmed | Requires careful callibration using standardised gas. Needs expertise to callibrate. |
Research quality treadmill | HP Cosmos Treadmill | Health & Safety requirements. |
Sonography equipment | Diasus Ultrasound | Requires expert user |